Pt-100 RTD Four Point Alarm

Drag Drop Image anywhere on Screen with Left Button - Zoom in or Zoom out with Scroll Wheel

Pt-100 RTD Four Point Alarm
Pt-100 RTD Four Point Alarm
Drag Drop with Mouse - Left Click and Hold the Image, then move the mouse to position the image where you want - Panning.
Scroll Zoom - Mouse Scroll Wheel can be roated in either direction to Zoom in or Zoom out, refresh page for normal image.

Here 4052 is used as an analog multiplexer, U3A TL062 opamp is wired as a 1mA Constant Current Source. It pumps 1mA into U2 4052 pin 13 X . Depending on BCD code on inputs A, B of 4052 the current is routed to any one of the four RTD 100E, whose one end is connected to X0-X3. The current then flows to GND thru the Platinum 100E resistance. The Y0-Y3 monitors the mV developed on RTD in tandem with X0-X3 positions. Like a ganged rotary switch. The Output mV at Y is the mV of Active Channel as selected by the BCD of 4029.

See another way 4052 is used to route analog signals to DPM - Analog mV Switch for Digital Meters

The BCD is provided by 4029 counter which is clocked by a 555. U5A cancels out the 100E mV (1mA * 100E) of a cold RTD and Amplifies the differential mV. This output of U5A is in proportion with measured temperature. U5B compares the mV that was obtained with a preset mV of POT1, which is a user setting called setpoint. The difference is amplified by U5B which is saturated by U3B comparator which adds a little hysteresis too. R7-C2 further dampen and slow the response. This finally drives Q2 to provide a Logic Signal indicating if temperature is below or above setpoint.

It is important to understand process control theory and the material technologies that go into these sensors too.

Here is a instrument i used to make in a similar need - Multizone Process Scanner

Four points in a Closed Loop Temperature Control System is Monitored and a Alarm set to go off when the temperature goes beyond the set limit.